ADIS16448 Set Calibration Time.vi

This VI triggers a re-calibration routine on the ADIS16470. This call will take approx. 100ms to run. The sensor <b><u>MUST</b></u> be completely still before calling this method. To set the amount of time before this call to calibrate call <b>ADIS16470 Set Re-calibration Time</b>. The default is ~1s.

A good use for this is to set the calibration time so a reasonable amount of time that the robot may be still (for example, while the robot is on the field before Autonomous). Then call this routine at the start of autonomous to set good calibration. The sensor uses the samples before this method is called in its calibration. The longer the time the better the result, though the improvement is lower after 8s-16s.


Connector Pane

ADIS16448 Set Calibration Time.vi


Front Panel

ADIS16448 Set Calibration Time.vi


Controls and Indicators

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ccclst

ADIS16448DevRef in

cenum

Calibration Time

icclst

ADIS16448DevRef out

ierrcodeclst

error out

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.